- IBM Netezza 1000-Series Site Preparation and Specifications Revised: June 17, 2011 D20281-18 Rev. 11.0 Note: Before using this information and the product that it supports, read the information in “Notices and Trademarks” on page B-1. © Copyright IBM Corporation 2001-2011. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Preface 1 IBM Netezza 1000 System Models 1000-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1000-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1000-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1000-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1000-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1000-36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1000-48 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 1000-72 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 1000-84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1000-96 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 1000-120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 2 1000-3 Specifications Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 3 1000-6 Specifications Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 4 1000-12 Specifications Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 iii 5 1000-18 Specifications Space requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 6 1000-24 Specifications Space requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 7 1000-36 Specifications Space requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4 8 1000-48 Specifications Space requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4 9 1000-72 Specifications Space requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5 iv 10 1000-84 Specifications Space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1 Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-5 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-5 11 1000-96 Specifications Space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1 Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4 12 1000-120 Specifications Space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-1 Electrical Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-4 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-4 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-5 Host Server Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-5 Appendix A: Model Comparison Appendix B: Notices and Trademarks Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 Open Source Notifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4 Regulatory and Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6 v vi Tables Table 2-1: Table 2-2: Table 2-3: Table 2-4: Table 2-5: Table 3-1: Table 3-2: Table 3-3: Table 3-4: Table 3-5: Table 4-1: Table 4-2: Table 4-3: Table 4-4: Table 4-5: Table 5-1: Table 5-2: Table 5-3: Table 5-4: Table 5-5: Table 6-1: Table 6-2: Table 6-3: Table 6-4: Table 6-5: Table 7-1: Table 7-2: Table 7-3: Table 7-4: Table 7-5: Table 8-1: Table 8-2: Table 8-3: 1000-3 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 1000-3 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 1000-3 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 1000-3 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . 2-3 IBM x3650 M3 Host Specifications. . . . . . . . . . . . . . . . . . . . . . . . . 2-4 1000-6 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 1000-6 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 1000-6 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 1000-6 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . . 3-3 IBM x3650 M3 Host Specifications. . . . . . . . . . . . . . . . . . . . . . . . . 3-4 1000-12 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 1000-12 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 1000-12 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 1000-12 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . 4-3 IBM x3650 M3 Host Specifications. . . . . . . . . . . . . . . . . . . . . . . . . 4-4 1000-18 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 1000-18 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 1000-18 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 1000-18 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . 5-3 IBM x3850 X5 Host Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 1000-24 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 1000-24 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 1000-24 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 1000-24 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . 6-3 IBM x3850 X5 Host Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 1000-36 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 1000-36 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 1000-36 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 1000-36 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . 7-3 IBM x3850 X5 Host Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 7-4 1000-48 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 1000-48 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 1000-48 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 vii Table 8-4: Table 8-5: Table 9-1: Table 9-2: Table 9-3: Table 9-4: Table 9-5: Table 10-1: Table 10-2: Table 10-3: Table 10-4: Table 10-5: Table 11-1: Table 11-2: Table 11-3: Table 11-4: Table 11-5: Table 12-1: Table 12-2: Table 12-3: Table 12-4: Table 12-5: Table A-1: 1000-48 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . 8-3 IBM x3850 X5 Host Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 8-4 1000-72 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 1000-72 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 1000-72 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 1000-72 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . . 9-5 IBM x3850 X5 Host Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 9-5 1000-84 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1 1000-84 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 1000-84 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 1000-84 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . 10-5 IBM x3850 X5 Host Specifications . . . . . . . . . . . . . . . . . . . . . . . . 10-5 1000-96 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1 1000-96 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 1000-96 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 1000-96 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . . 11-4 IBM x3850 X5 Host Specifications . . . . . . . . . . . . . . . . . . . . . . . . 11-4 1000-120 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 12-1 1000-120 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . 12-4 1000-120 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . 12-4 1000-120 Floor Loading Requirements . . . . . . . . . . . . . . . . . . . . . 12-5 IBM x3850 X5 Host Specifications . . . . . . . . . . . . . . . . . . . . . . . . 12-5 Model Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 viii Figures Figure 1-1: Figure 1-2: Figure 1-3: Figure 1-4: Figure 1-5: Figure 1-6: Figure 1-7: Figure 1-8: Figure 1-9: Figure 1-10: Figure 1-11: Figure 1-12: Figure 1-13: Figure 1-14: Figure 1-15: Figure 1-16: Figure 2-1: Figure 3-1: Figure 4-1: Figure 5-1: Figure 6-1: Figure 7-1: Figure 8-1: Figure 9-1: Figure 9-2: Figure 9-3: Figure 10-1: Figure 10-2: Figure 10-3: Figure 11-1: Figure 11-2: Figure 12-1: Figure 12-2: Figure 12-3: 1000-3 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1000-6 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1000-12 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1000-18 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1000-24 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1000-36 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1000-48 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 1000-72 Pod 1 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 1000-72 Pod 2 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 1000-84 Pod1 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1000-84 Pod 2 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1000-96 Pod1 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 1000-96 Pod 2 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 1000-120 Pod1 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 1000-120 Pod 2 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 1000-120 Pod 3 (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 Rack Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Rack Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Rack Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Space Requirements for a 2-Rack Pod . . . . . . . . . . . . . . . . . . . . . . . 5-2 Space Requirements for a 2-Rack Pod . . . . . . . . . . . . . . . . . . . . . . . 6-2 Space Requirements for a 3-Rack Pod . . . . . . . . . . . . . . . . . . . . . . . 7-2 Space Requirements for a 4-Rack Pod . . . . . . . . . . . . . . . . . . . . . . . 8-2 Space Requirements for a 4-Rack Pod . . . . . . . . . . . . . . . . . . . . . . . 9-2 Space Requirements for a 2-Rack Pod . . . . . . . . . . . . . . . . . . . . . . . 9-3 Pod Positioning for Multiple Pods . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3 Space Requirements for each 4-Rack Pod . . . . . . . . . . . . . . . . . . . 10-2 Space Requirements for each 3-Rack Pod . . . . . . . . . . . . . . . . . . . 10-2 Pod Positioning for Multiple Pods . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 Space Requirements for each 4-Rack Pod . . . . . . . . . . . . . . . . . . . 11-2 Pod Positioning for Multiple Pods . . . . . . . . . . . . . . . . . . . . . . . . . 11-2 Space Requirements for each 4-Rack Pod . . . . . . . . . . . . . . . . . . . 12-2 Space Requirements for a 2-Rack Pod . . . . . . . . . . . . . . . . . . . . . . 12-3 Pod Positioning for Multiple Pods . . . . . . . . . . . . . . . . . . . . . . . . . 12-3 ix x Preface The IBM Netezza 1000 system is a high-performance, integrated data warehouse appliance that provides unparalleled performance, extensive scaling, high reliability, and ease of use. The system uses a unique architecture that combines current trends in processor, network, and software technologies to deliver a very high-performance system for large enterprise customers. About This Guide IBM Netezza 1000 Series Site Preparation and Specifications is written for those who need to understand the site requirements and specifications of each IBM Netezza 1000 model. This guide assumes that you understand the capabilities and capacities of the physical space in which you are installing a IBM Netezza 1000 system. The guide describes the hardware components that make up the system, and discusses the following: Preparing a physical location. Maintaining a location. Various IBM Netezza 1000 models. Hardware specifications. Included in This Guide This guide is designed to be used before and during installation of the IBM Netezza 1000 system. It contains important information on preparing and maintaining your site. It specifically covers the following topics: Chapter 1, “IBM Netezza 1000 System Models” — Lists the different system models and describes the location of the major components within the system. Chapter 2, “1000-3 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 3 system. Chapter 3, “1000-6 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 6 system. Chapter 4, “1000-12 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 18 system. Chapter 5, “1000-18 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 12 system. Chapter 6, “1000-24 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 24 system. Chapter 7, “1000-36 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 36 system. Chapter 8, “1000-48 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 48 system. xi Chapter 9, “1000-72 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 72 system. Chapter 10, “1000-84 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 84 system. Chapter 11, “1000-96 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 96 system. Chapter 12, “1000-120 Specifications” — Provides the information necessary to prepare your site for the installation of the IBM Netezza 1000 120 system. Appendix A, “Model Comparison” — Provides a model comparison of the systems in the current IBM Netezza 1000 product line. xii Symbols and Conventions This guide uses the following typographical conventions: Numbered steps for procedures Single-step procedures are preceded by the q symbol Bulleted lists for topics Italics for terms, and user-defined variables such as filenames Abbreviations This guide uses the following abbreviations throughout: Abbreviation A ACID GB HTTP Hz in. kg KVA KVM lb m Mb MB ms MSFI MSPU NIC NPS PCI Description ampere Atomicity, Consistency, Isolation, and Durability Gigabyte HyperText Transport Protocol Hertz Inch Kilogram Kilo Volt-Amps Keyboard-Video-Mouse Pound meter Megabit Megabyte Milliseconds Mustang Snippet Fabric Interface Mustang Snippet Processing Unit Network Interface Card Netezza Performance Software Peripheral Component Interconnect xiii Abbreviation PCIe PCIx PDU RAID RPC SAS SATA SCSI SFI SNMP SPA SPU TB VAC Description PCI Express PCI eXtended Power Distribution Unit Redundant Array of Independent Disks Remote Power Controller Serial Attached SCSI Serial Advanced Technology Attachment Small Computer System Interface Snippet Fabric Interface Simple Network Management Protocol Snippet Processing Array Snippet Processing Unit Terabyte Volts Alternating Current If You Need Help If you are having trouble using the IBM® Netezza® appliance, you should: 1. Retry the action, carefully following the instructions given for that task in the documentation. 2. Go to the Netezza Knowledge Base at https://knowledge.netezza.com. Enter your support username and password. You can search the knowledge base or the latest updates to the product documentation. Click Netezza HelpDesk to submit a support request. 3. If you are unable to access the Netezza Knowledge Base, you can also contact Netezza Support at the following telephone numbers: North American Toll-Free: +1.877.810.4441 United Kingdom Free-Phone: +0.800.032.8382 International Direct: +1.508.620.2281 Refer to your Netezza maintenance agreement for details about your support plan choices and coverage. xiv Comments on the Documentation We welcome any questions, comments, or suggestions that you have for the IBM Netezza documentation. Please send us an e-mail message at netezza-doc@wwpdl.vnet.ibm.com and include the following information: The name and version of the manual that you are using Any comments that you have about the manual Your name, address, and phone number We appreciate your comments on the documentation. D20281-18 Rev.11.0 i-xv IBM Netezza 1000-Series Site Preparation and Specifications i-xvi D20281-18 Rev.11.0 CHAPTER 1 IBM Netezza 1000 System Models This chapter contains the following information: A description of each system, including the number of racks, S-Blades, and SPAs in the system An illustration of each system showing the placement of components within each rack. 1000-3 The 1000-3 is a single-rack system containing 3 S-Blades housed in 1 SPA. Figure 1-1 shows a 1000-3 system. Note: The switch is only visible from the rear of the rack. Host 1 (x3650) Host 2 (x3650) KVM Mgt Switch JBOD JBOD S-Blades Figure 1-1: 1000-3 (front view) 1-1 IBM Netezza 1000-Series Site Preparation and Specifications 1000-6 The 1000-6 is a single-rack system containing 6 S-Blades housed in 1 SPA. Figure 1-2 shows a 1000-6 system. Note: The switch is only visible from the rear of the rack. Host 1 (x3650) Host 2 (x3650) KVM Mgt Switch JBOD JBOD JBOD JBOD S-Blades Figure 1-2: 1000-6 (front view) 1-2 D20281-18 Rev.11.0 1000-12 1000-12 The 1000-12 is a single-rack system containing 12 S-Blades housed in 2 SPAs. Figure 1-3 shows a 1000-12 system. Note: The switch is only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3650) Host 2 (x3650) KVM Mgt Switch S-Blades S-Blades Figure 1-3: 1000-12 (front view) D20281-18 Rev.11.0 1-3 IBM Netezza 1000-Series Site Preparation and Specifications 1000-18 The 1000-18 is a two-rack system containing 18 S-Blades housed in 3 SPAs. Note: The racks are bolted together into a single unit and cannot be separated. Figure 1-3 shows a 1000-18 system. Note: The switches are only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3850 M2) KVM Mgt Switch Host 2 (x3850 M2) Fabric Switch Fabric Switch JBOD S-Blades JBOD JBOD JBOD S-Blades S-Blades Figure 1-4: 1000-18 (front view) 1-4 D20281-18 Rev.11.0 1000-24 1000-24 The 1000-24 is a two-rack system containing 24 S-Blades housed in 4 SPAs. Note: The racks are bolted together into a single unit and cannot be separated. Figure 1-3 shows a 1000-24 system. Note: The switches are only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3850 M2) KVM Mgt Switch Host 2 (x3850 M2) Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades Figure 1-5: 1000-24 (front view) D20281-18 Rev.11.0 1-5 IBM Netezza 1000-Series Site Preparation and Specifications 1000-36 The 1000-36 is a three-rack system containing 36 S-Blades housed in 6 SPAs. Note: The racks are bolted together into a single unit and cannot be separated. Figure 1-3 shows a 1000-36 system. Note: The switches are only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3850 M2) KVM Mgt Switch Host 2 (x3850 M2) Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-6: 1000-36 (front view) 1-6 D20281-18 Rev.11.0 1000-48 1000-48 The 1000-48 is a four-rack system containing 48 S-Blades housed in 8 SPAs. Note: The racks are bolted together into a single unit and cannot be separated. Figure 1-3 shows a 1000-48 system. Note: The switches are only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3850 M2) KVM Mgt Switch Host 2 (x3850 M2) Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-7: 1000-48 (front view) D20281-18 Rev.11.0 1-7 IBM Netezza 1000-Series Site Preparation and Specifications 1000-72 The 1000-72 is a six-rack system containing 72 S-Blades housed in 12 SPAs. Note: The racks are bolted together into two distinct units, known as pods. Pods may be located separately from each other, limited by the length (20 meters) of the inter-pod cables. Pods may not be broken apart into individual racks. Figure 1-3 shows a 1000-72 system. Note: The switches are only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3850 M2) KVM Mgt Switch Host 2 (x3850 M2) Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-8: 1000-72 Pod 1 (front view) JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD KVM Mgt Switch Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades Figure 1-9: 1000-72 Pod 2 (front view) 1-8 D20281-18 Rev.11.0 1000-84 1000-84 The 1000-84 is a seven-rack system containing 84 S-Blades housed in 14 SPAs. Note: The racks are bolted together into two distinct units, known as pods. Pods may be located separately from each other, limited by the length (20 meters) of the inter-pod cables. Pods may not be broken apart into individual racks. Figure 1-3 shows a 1000-84 system. Note: The switches are only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3850 M2) KVM Mgt Switch Host 2 (x3850 M2) Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-10: 1000-84 Pod1 (front view) JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD KVM Mgt Switch Fabric Switch Fabric Switch Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-11: 1000-84 Pod 2 (front view) D20281-18 Rev.11.0 1-9 IBM Netezza 1000-Series Site Preparation and Specifications 1000-96 The 1000-96 is a eight-rack system containing 96 S-Blades housed in 16 SPAs. Note: The racks are bolted together into two distinct units, known as pods. Pods may be located separately from each other, limited by the length (20 meters) of the inter-pod cables. Pods may not be broken apart into individual racks. Figure 1-3 shows a 1000-96 system. Note: The switches are only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3850 M2) KVM Mgt Switch Host 2 (x3850 M2) Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-12: 1000-96 Pod1 (front view) JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD KVM Mgt Switch Fabric Switch Fabric Switch Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-13: 1000-96 Pod 2 (front view) 1-10 D20281-18 Rev.11.0 1000-120 1000-120 The 1000-120 is a ten-rack system containing 120 S-Blades housed in 20 SPAs. Note: The racks are bolted together into three distinct units, known as pods. Pods may be located separately from each other, limited by the length (20 meters) of the inter-pod cables. Pods may not be broken apart into individual racks. Figure 1-3 shows a 1000-120 system. Note: The switches are only visible from the rear of the rack. JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD Host 1 (x3850 M2) KVM Mgt Switch Host 2 (x3850 M2) Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-14: 1000-120 Pod1 (front view) JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD KVM Mgt Switch Fabric Switch Fabric Switch Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades S-Blades Figure 1-15: 1000-120 Pod 2 (front view) D20281-18 Rev.11.0 1-11 IBM Netezza 1000-Series Site Preparation and Specifications JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD JBOD KVM Mgt Switch Fabric Switch Fabric Switch S-Blades S-Blades S-Blades S-Blades Figure 1-16: 1000-120 Pod 3 (front view) 1-12 D20281-18 Rev.11.0 CHAPTER 2 1000-3 Specifications This chapter explains the following requirements for the 1000-3 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Electrical Power Requirements Each 1000-3 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 2-1. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 2-1: 1000-3 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage Circuit Breaker Rating Connector Value 2 2 200-240 VAC, 50Hz/60 Hz (Single Phase) 20 Amps (Single Phase) NEMA 30A L6-30 (NA models) IEC 309 32A 2P+G (EU models) 2,930 W 385 W/ft2 (4,141 W/m2) Maximum Power Power/Area 2-1 IBM Netezza 1000-Series Site Preparation and Specifications Space requirements Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The 1000-series systems are housed in a rack that is 1.5 in. (3.8 cm) wider than previous Netezza systems. This means that the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Figure 2-1 shows the space requirements for each rack. 25.5 in (64.8 cm) 30 in (76 cm) 40 in (101.6 cm) 36 in 91.5 cm) 60 in (152 cm) between rows Figure 2-1: Rack Space Requirements The total space requirements for the 1000-3 system are listed in Table 2-2. Table 2-2: 1000-3 Space Requirements Physical Footprint (WxD) 25.5 in. by 43 in. (64.8 cm x 109.2 cm) Including Clearance 25.5 in. by 130 in. (64.8 cm x 330.2 cm) 2-2 D20281-18 Rev.11.0 Environmental Requirements Environmental Requirements The 1000-3 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 2-3: 1000-3 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 9,998 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing Humidity Cooling Floor Loading Requirements The floor that supports the 1000-3 system must be capable of supporting a minimum of 132 lbs/ft2 (642 kg/m2). Table 2-4: 1000-3 Floor Loading Requirements Specification Maximum Weight Value 1,000 lb (453.6 kg) 131.3 lb/ft2 (641.1 kg/m2) Maximum Weight/Area D20281-18 Rev.11.0 2-3 IBM Netezza 1000-Series Site Preparation and Specifications Host Server Specifications Table 2-5: IBM x3650 M3 Host Specifications Feature Processors Memory Power supplies Fans NIC Number two — two three four ports (two available) one quad port card (two available) one dual port card (one available) one Description Quad-core Intel Xeon 2.4 GHz, 12MB L3 1066MHz 80w 24 GB, PC3-10600 (DDR3) SDRAM 675W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Four Gigabit ethernet ports (embedded) NIC One Quad Port PCIe Gigabit Adapter NIC IMM port One Dual Port PCIe 10 Gigabit Adapter Integrated Management Module dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Four PCI-Express x8 (one full length, one half length, two low profile) Two front, two rear, one internal 300 GB SAS drives PCI slots seven four (two available) USB 2.0 ports Serial port DVD-ROM/CD-RW Form Factor Management five one one 2U (3.5”) 8X / 24X max rack-mountable IMM 2-4 D20281-18 Rev.11.0 CHAPTER 3 1000-6 Specifications This chapter explains the following requirements for the 1000-6 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Electrical Power Requirements Each 1000-6 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 3-1. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 3-1: 1000-6 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage Circuit Breaker Rating Connector Value 2 2 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (Single Phase) NEMA 30A L6-30 (NA models) IEC 309 32A 2P+G (EU models) 4,120 W 541 W/ft2 (5,822 W/m2) Maximum Power Power/Area 3-1 IBM Netezza 1000-Series Site Preparation and Specifications Space requirements Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The 1000-series system is housed in a rack that is 1.5 in. (3.8 cm) wider than previous Netezza systems. This means that the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Figure 3-1 shows the space requirements for each rack. 25.5 in (64.8 cm) 30 in (76 cm) 40 in (101.6 cm) 36 in 91.5 cm) 60 in (152 cm) between rows Figure 3-1: Rack Space Requirements The total space requirements for the 1000-6 system are listed in Table 3-2. Table 3-2: 1000-6 Space Requirements Physical Footprint (WxD) 25.5 in. by 43 in. (64.8 cm x 109.2 cm) Including Clearance 25.5 in. by 130 in. (64.8 cm x 330.2 cm) 3-2 D20281-18 Rev.11.0 Environmental Requirements Environmental Requirements The 1000-6 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 3-3: 1000-6 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 14,058 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing Humidity Cooling Floor Loading Requirements The floor that supports the 1000-6 system must be capable of supporting a minimum of 171 lbs/ft2 (834 kg/m2). Table 3-4: 1000-6 Floor Loading Requirements Specification Maximum Weight Value 1,300 lb (589.7 kg) 170.7 lb/ft2 (833.4 kg/m2) Maximum Weight/Area D20281-18 Rev.11.0 3-3 IBM Netezza 1000-Series Site Preparation and Specifications Host Server Specifications Table 3-5: IBM x3650 M3 Host Specifications Feature Processors Memory Power supplies Fans NIC Number two — two three four ports (two available) one quad port card (two available) one dual port card (one available) one Description Quad-core Intel Xeon 2.4 GHz, 12MB L3 1066MHz 80w 24 GB, PC3-10600 (DDR3) SDRAM 675W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Four Gigabit ethernet ports (embedded) NIC One Quad Port PCIe Gigabit Adapter NIC IMM port One Dual Port PCIe 10 Gigabit Adapter Integrated Management Module dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Four PCI-Express x8 (one full length, one half length, two low profile) Two front, two rear, one internal 300 GB SAS drives PCI slots seven four (two available) USB 2.0 ports Serial port DVD-ROM/CD-RW Form Factor Management five one one 2U (3.5”) 8X / 24X max rack-mountable IMM 3-4 D20281-18 Rev.11.0 CHAPTER 4 1000-12 Specifications This chapter explains the following requirements for the 1000-12 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Electrical Power Requirements Each 1000-12 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 4-1. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 4-1: 1000-12 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage Value 2 2 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 7,220 W 948 W/ft2 (10,203 W/m2) Circuit Breaker Rating Connector Maximum Power Power/Area 4-1 IBM Netezza 1000-Series Site Preparation and Specifications Space requirements Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The 1000-series system is housed in a rack that is 1.5 in. (3.8 cm) wider than previous Netezza systems. This means that the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Figure 4-1 shows the space requirements for each rack. 25.5 in (64.8 cm) 30 in (76 cm) 40 in (101.6 cm) 36 in 91.5 cm) 60 in (152 cm) between rows Figure 4-1: Rack Space Requirements The total space requirements for the 1000-12 system are listed in Table 4-2. Table 4-2: 1000-12 Space Requirements Physical Footprint (WxD) 25.5 in. by 43 in. (64.8 cm x 109.2 cm) Including Clearance 25.5 in. by 130 in. (64.8 cm x 330.2 cm) 4-2 D20281-18 Rev.11.0 Environmental Requirements Environmental Requirements The 1000-12 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 4-3: 1000-12 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 24,636 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Humidity Cooling Floor Loading Requirements The floor that supports the 1000-12 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 4-4: 1000-12 Floor Loading Requirements Specification Maximum Weight Value 2,000 lb (907.2 kg) 262.7 lb/ft2 (1,282.6 kg/m2) Maximum Weight/Area D20281-18 Rev.11.0 4-3 IBM Netezza 1000-Series Site Preparation and Specifications Host Server Specifications Table 4-5: IBM x3650 M3 Host Specifications Feature Processors Memory Power supplies Fans NIC Number two — two three four ports (two available) one quad port card (two available) one dual port card (one available) one Description Quad-core Intel Xeon 2.4 GHz, 12MB L3 1066MHz 80w 24 GB, PC3-10600 (DDR3) SDRAM 675W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Four Gigabit ethernet ports (embedded) NIC One Quad Port PCIe Gigabit Adapter NIC IMM port One Dual Port PCIe 10 Gigabit Adapter Integrated Management Module dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Four PCI-Express x8 (one full length, one half length, two low profile) Two front, two rear, one internal 300 GB SAS drives PCI slots seven four (two available) USB 2.0 ports Serial port DVD-ROM/CD-RW Form Factor Management five one one 2U (3.5”) 8X / 24X max rack-mountable IMM 4-4 D20281-18 Rev.11.0 CHAPTER 5 1000-18 Specifications This chapter explains the following requirements for the 1000-18 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Space requirements The 1000-18 consists of two racks. The racks are bolted together into a group of racks called a pod. In this system there is a single pod of two racks. Rack Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The racks that are used for 1000-series systems are 1.5 in. (3.8 cm) wider than those used in previous Netezza systems. This means that each rack in the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Pods The 1000-18 consists of a pod with two racks. The space requirements for the pod are listed in Table 5-1. Table 5-1: 1000-18 Space Requirements Footprint Number of Racks Physical 2 51 in. by 43 in. (128.6 cm x 109.2 cm) Including Clearance 51 in. by 130 in. (128.6 cm x 330.2 cm) Figure 5-1 shows the space requirements for the pod. 5-1 IBM Netezza 1000-Series Site Preparation and Specifications 51 in (129.6 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 5-1: Space Requirements for a 2-Rack Pod Electrical Power Requirements Each 1000-18 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 5-2. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 5-2: 1000-18 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage 2-Rack Pod 2 4 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 11,060 W Circuit Breaker Rating Connector Maximum Power 5-2 D20281-18 Rev.11.0 Environmental Requirements Table 5-2: 1000-18 Electrical Requirements Specification Power/Area 2-Rack Pod 726 W/ft2 (7,815 W/m2) Environmental Requirements The 1000-18 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 5-3: 1000-18 Operating Environment Operating Temperature 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 37,738 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Altitude Humidity Cooling Floor Loading Requirements The floor that supports the 1000-18 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 5-4: 1000-18 Floor Loading Requirements Specification Maximum Weight 2-Rack Pod 3,000 lb (1360.8 kg) 195.8 lb/ft2 (958.3 kg/m2) Maximum Weight/Area D20281-18 Rev.11.0 5-3 IBM Netezza 1000-Series Site Preparation and Specifications Host Server Specifications Table 5-5: IBM x3850 X5 Host Specifications Feature Processors Memory Power supplies Fans NIC NIC NIC Number four — two six two ports (two available) one quad port card (two available) three dual port card (internal use) one seven seven (three available) four one one 4U (7”) 8X / 24X max Rack-mountable IMM Description Six-core Intel Xeon 2.0 GHz, 18MB L3 1066MHz 105w 128 GB, PC3-8500 (DDR3-1066) RDIMMs 1975W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Two Gigabit ethernet ports (embedded) One Quad Port 1 Gigabit Adapter Three Dual Port 10 Gigabit Adapter IMM port 300 GB SAS drives PCI slots USB 2.0 ports Serial port DVD-ROM/CD-RW Form factor Management Remote Supervisor Adapter dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Seven PCIe (3 available) Two front, two rear 5-4 D20281-18 Rev.11.0 CHAPTER 6 1000-24 Specifications This chapter explains the following requirements for the 1000-24 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Space requirements The 1000-24 consists of two racks. The racks are bolted together into a group of racks called a pod. In this system there is a single pod of two racks. Rack Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The racks that are used for 1000-series systems are 1.5 in. (3.8 cm) wider than those used in previous Netezza systems. This means that each rack in the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Pods The 1000-24 consists of a pod with two racks. The space requirements for the pod are listed in Table 6-1. Table 6-1: 1000-24 Space Requirements Footprint Number of Racks Physical 2 51 in. by 43 in. (128.6 cm x 109.2 cm) Including Clearance 51 in. by 130 in. (128.6 cm x 330.2 cm) Figure 6-1 shows the space requirements for the pod. 6-1 IBM Netezza 1000-Series Site Preparation and Specifications 51 in (129.6 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 6-1: Space Requirements for a 2-Rack Pod Electrical Power Requirements Each 1000-24 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 6-2. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 6-2: 1000-24 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage 2-Rack Pod 2 4 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 14,160 W Circuit Breaker Rating Connector Maximum Power 6-2 D20281-18 Rev.11.0 Environmental Requirements Table 6-2: 1000-24 Electrical Requirements Specification Power/Area 2-Rack Pod 930 W/ft2 (10,005 W/m2) Environmental Requirements The 1000-24 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 6-3: 1000-24 Operating Environment Operating Temperature 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 48,316 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Altitude Humidity Cooling Floor Loading Requirements The floor that supports the 1000-24 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 6-4: 1000-24 Floor Loading Requirements Specification Maximum Weight 2-Rack Pod 4,000 lb (1814.4 kg) 262.7 lb/ft2 (1,282.6 kg/m2) Maximum Weight/Area D20281-18 Rev.11.0 6-3 IBM Netezza 1000-Series Site Preparation and Specifications Host Server Specifications Table 6-5: IBM x3850 X5 Host Specifications Feature Processors Memory Power supplies Fans NIC NIC NIC Number four — two six two ports (two available) one quad port card (two available) three dual port card (internal use) one seven seven (three available) four one one 4U (7”) 8X / 24X max Rack-mountable IMM Description Six-core Intel Xeon 2.0 GHz, 18MB L3 1066MHz 105w 128 GB, PC3-8500 (DDR3-1066) RDIMMs 1975W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Two Gigabit ethernet ports (embedded) One Quad Port 1 Gigabit Adapter Three Dual Port 10 Gigabit Adapter IMM port 300 GB SAS drives PCI slots USB 2.0 ports Serial port DVD-ROM/CD-RW Form factor Management Remote Supervisor Adapter dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Seven PCIe (3 available) Two front, two rear 6-4 D20281-18 Rev.11.0 CHAPTER 7 1000-36 Specifications This chapter explains the following requirements for the 1000-36 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Space requirements The 1000-36 consists of three racks. The racks are bolted together into a group of racks called a pod. In this system there is a single pod of three racks. Rack Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The racks that are used for 1000-series systems are 1.5 in. (3.8 cm) wider than those used in previous Netezza systems. This means that each rack in the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Pods The 1000-36 consists of one 3-rack pod. The space requirements for the pod are listed in Table 7-1. Table 7-1: 1000-36 Space Requirements Footprint Number of Racks Physical 3 76.5 in. by 43 in. (194.3 cm x 109.2 cm) Including Clearance 76.5 in. by 130 in. (194.3 cm x 330.2 cm) 7-1 IBM Netezza 1000-Series Site Preparation and Specifications Figure 7-1 shows the space requirements for the Pod. 76.5 in (194.3 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 7-1: Space Requirements for a 3-Rack Pod Electrical Power Requirements Each 1000-36 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 7-2. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 7-2: 1000-36 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage 3-Rack Pod 2 6 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 20,360 W Circuit/Breaker Rating Connector Maximum Power 7-2 D20281-18 Rev.11.0 Environmental Requirements Table 7-2: 1000-36 Electrical Requirements Specification Power/Area 3-Rack Pod 891 W/ft2 (9,591 W/m2) Environmental Requirements The 1000-36 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 7-3: 1000-36 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 69,471 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Humidity Cooling Floor Loading Requirements The floor that supports the 1000-36 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 7-4: 1000-36 Floor Loading Requirements Specification Maximum Weight Maximum Weight/Area 3-Rack Pod 6,000 lb (2721.6 kg) 262.7 lb/ft2 (1,282.6 kg/m2) D20281-18 Rev.11.0 7-3 IBM Netezza 1000-Series Site Preparation and Specifications Host Server Specifications Table 7-5: IBM x3850 X5 Host Specifications Feature Processors Memory Power supplies Fans NIC NIC NIC Number four — two six two ports (two available) one quad port card (two available) three dual port card (internal use) one seven seven (three available) four one one 4U (7”) 8X / 24X max Rack-mountable IMM Description Six-core Intel Xeon 2.0 GHz, 18MB L3 1066MHz 105w 128 GB, PC3-8500 (DDR3-1066) RDIMMs 1975W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Two Gigabit ethernet ports (embedded) One Quad Port 1 Gigabit Adapter Three Dual Port 10 Gigabit Adapter IMM port 300 GB SAS drives PCI slots USB 2.0 ports Serial port DVD-ROM/CD-RW Form factor Management Remote Supervisor Adapter dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Seven PCIe (3 available) Two front, two rear 7-4 D20281-18 Rev.11.0 CHAPTER 8 1000-48 Specifications This chapter explains the following requirements for the 1000-48 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Space requirements The 1000-48 consists of four racks. The racks are bolted together into a group of racks called a pod. In this system there is a single pod of four racks. Rack Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The racks that are used for 1000-series systems are 1.5 in. (3.8 cm) wider than those used in previous Netezza systems. This means that each rack in the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Pods The 1000-48 consists of one 4-rack pod. The space requirements for the pod are listed in Table 8-1. Table 8-1: 1000-48 Space Requirements Footprint Number of Racks Physical 4 102 in. by 43 in. (259.2 cm x 109.2 cm) Including Clearance 102 in. by 130 in. (259.2 cm x 330.2 cm) 8-1 IBM Netezza 1000-Series Site Preparation and Specifications Figure 8-1 shows the space requirements for the Pod. 102 in (259.1 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 8-1: Space Requirements for a 4-Rack Pod Electrical Power Requirements Each 1000-48 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 8-2. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 8-2: 1000-48 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage 4-Rack Pod 2 8 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 26,560 W Circuit/Breaker Rating Connector Maximum Power 8-2 D20281-18 Rev.11.0 Environmental Requirements Table 8-2: 1000-48 Electrical Requirements Specification Power/Area 4-Rack Pod 872 W/ft2 (9,384 W/m2) Environmental Requirements The 1000-48 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 8-3: 1000-48 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 90,627 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Humidity Cooling Floor Loading Requirements The floor that supports the 1000-48 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 8-4: 1000-48 Floor Loading Requirements Specification Maximum Weight Maximum Weight/Area 4-Rack Pod 8,000 lb (3628.8 kg) 262.7 lb/ft2 (1,282.6 kg/m2) D20281-18 Rev.11.0 8-3 IBM Netezza 1000-Series Site Preparation and Specifications Host Server Specifications Table 8-5: IBM x3850 X5 Host Specifications Feature Processors Memory Power supplies Fans NIC NIC NIC Number four — two six two ports (two available) one quad port card (two available) three dual port card (internal use) one seven seven (three available) four one one 4U (7”) 8X / 24X max Rack-mountable IMM Description Six-core Intel Xeon 2.0 GHz, 18MB L3 1066MHz 105w 128 GB, PC3-8500 (DDR3-1066) RDIMMs 1975W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Two Gigabit ethernet ports (embedded) One Quad Port 1 Gigabit Adapter Three Dual Port 10 Gigabit Adapter IMM port 300 GB SAS drives PCI slots USB 2.0 ports Serial port DVD-ROM/CD-RW Form factor Management Remote Supervisor Adapter dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Seven PCIe (3 available) Two front, two rear 8-4 D20281-18 Rev.11.0 CHAPTER 9 1000-72 Specifications This chapter explains the following requirements for the 1000-72 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Space requirements The 1000-72 consists of a total of six racks. The racks are bolted together into separate groups called pods. In this system there are a total of two pods; one pod of four racks, and one pod of two racks. Rack Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The racks that are used for 1000-series systems are 1.5 in. (3.8 cm) wider than those used in previous Netezza systems. This means that each rack in the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Pods The 1000-72 consists of two separate pods. The space requirements for each pod are listed in Table 9-1. Table 9-1: 1000-72 Space Requirements Footprint Number of Racks Physical Pod 1 4 102 in. by 43 in. (259.2 cm x 109.2 cm) Including Clearance 102 in. by 130 in. (259.2 cm x 330.2 cm) 9-1 IBM Netezza 1000-Series Site Preparation and Specifications Table 9-1: 1000-72 Space Requirements Footprint Number of Racks Physical Pod 2 2 51 in. by 43 in. (128.6 cm x 109.2 cm) Including Clearance 51 in. by 130 in. (128.6 cm x 330.2 cm) Figure 9-1 shows the space requirements for Pod 1. 102 in (259.1 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 9-1: Space Requirements for a 4-Rack Pod 9-2 D20281-18 Rev.11.0 Space requirements Figure 9-2 shows the space requirements for Pod 2. 51 in (129.6 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 9-2: Space Requirements for a 2-Rack Pod When positioning the pods, they may be placed side-by-side, front-to-front, or rear-to-rear. Spacing between pods placed front-to-front or rear-to-rear must be as shown in Figure 9-3. 102 in (152 cm) Figure 9-3: Pod Positioning for Multiple Pods D20281-18 Rev.11.0 9-3 IBM Netezza 1000-Series Site Preparation and Specifications Electrical Power Requirements Each 1000-72 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 9-2. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 9-2: 1000-72 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage 8 Pod 1 Pod 2 2 4 12 Total System 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 26,560 W 12,960 W 865 W/ft2 (9,308 W/m2) 39,520 W Circuit/Breaker Rating Connector Maximum Power Power/Area Environmental Requirements The 1000-72 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 9-3: 1000-72 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 134,848 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Humidity Cooling 9-4 D20281-18 Rev.11.0 Floor Loading Requirements Floor Loading Requirements The floor that supports the 1000-72 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 9-4: 1000-72 Floor Loading Requirements Specification Maximum Weight Maximum Weight/Area Pod 1 8,000 lb (3628.8 kg) Pod 2 4,000 lb (1814.4 kg) 262.7 lb/ft2 (1,282.6 kg/m2) Host Server Specifications Table 9-5: IBM x3850 X5 Host Specifications Feature Processors Memory Power supplies Fans NIC NIC NIC Number four — two six two ports (two available) one quad port card (two available) three dual port card (internal use) one seven seven (three available) four one one 8X / 24X max Description Six-core Intel Xeon 2.0 GHz, 18MB L3 1066MHz 105w 128 GB, PC3-8500 (DDR3-1066) RDIMMs 1975W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Two Gigabit ethernet ports (embedded) One Quad Port 1 Gigabit Adapter Three Dual Port 10 Gigabit Adapter IMM port 300 GB SAS drives PCI slots USB 2.0 ports Serial port DVD-ROM/CD-RW Remote Supervisor Adapter dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Seven PCIe (3 available) Two front, two rear D20281-18 Rev.11.0 9-5 IBM Netezza 1000-Series Site Preparation and Specifications Table 9-5: IBM x3850 X5 Host Specifications Feature Form factor Management Number 4U (7”) Description Rack-mountable IMM 9-6 D20281-18 Rev.11.0 C H A P T E R 10 1000-84 Specifications This chapter explains the following requirements for the 1000-84 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Space requirements The 1000-84 consists of a total of seven racks. The racks are bolted together into separate groups called pods. In this system there are a total of two pods; one pod of four racks and one pod of three racks. Rack Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The racks that are used for 1000-series systems are 1.5 in. (3.8 cm) wider than those used in previous Netezza systems. This means that each rack in the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Pods The 1000-84 consists of two separate pods. The space requirements for each pod are listed in Table 10-1. Table 10-1: 1000-84 Space Requirements Number of Racks Pod 1 Pod 2 4 3 Footprint Physical 102 in. by 43 in. (259.2 cm x 109.2 cm) 76.5 in. by 43 in. (194.3 cm x 109.2 cm) Including Clearance 102 in. by 130 in. (259.2 cm x 330.2 cm) 76.5 in. by 130 in. (194.3 cm x 330.2 cm) 10-1 IBM Netezza 1000-Series Site Preparation and Specifications Figure 10-1 and Figure 10-2 show the space requirements for each pod. 102 in (259.1 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 10-1: Space Requirements for each 4-Rack Pod 76.5 in (194.3 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 10-2: Space Requirements for each 3-Rack Pod 10-2 D20281-18 Rev.11.0 Space requirements When positioning the pods, they may be placed side-by-side, front-to-front, or rear-to-rear. Spacing between pods placed front-to-front or rear-to-rear must be as shown in Figure 10-3. 102 in (152 cm) Figure 10-3: Pod Positioning for Multiple Pods D20281-18 Rev.11.0 10-3 IBM Netezza 1000-Series Site Preparation and Specifications Electrical Power Requirements Each 1000-84 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 10-2. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 10-2: 1000-84 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage 8 Pod 1 Pod 2 2 6 14 Total System 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 26,560 W 19,560 W 865 W/ft2 (9,310 W/m2) 46,120 W Circuit/Breaker Rating Connector Maximum Power Power/Area Environmental Requirements The 1000-84 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 10-3: 1000-84 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 178,523 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Humidity Cooling 10-4 D20281-18 Rev.11.0 Floor Loading Requirements Floor Loading Requirements The floor that supports the 1000-84 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 10-4: 1000-84 Floor Loading Requirements Specification Maximum Weight Maximum Weight/Area Pod 1 8,000 lb (3628.8 kg) Pod 2 6,000 lb (2721.6 kg) 262.7 lb/ft2 (1,282.6 kg/m2) Host Server Specifications Table 10-5: IBM x3850 X5 Host Specifications Feature Processors Memory Power supplies Fans NIC NIC NIC Number four — two six two ports (two available) one quad port card (two available) three dual port card (internal use) one seven seven (three available) four one one 8X / 24X max Description Six-core Intel Xeon 2.0 GHz, 18MB L3 1066MHz 105w 128 GB, PC3-8500 (DDR3-1066) RDIMMs 1975W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Two Gigabit ethernet ports (embedded) One Quad Port 1 Gigabit Adapter Three Dual Port 10 Gigabit Adapter IMM port 300 GB SAS drives PCI slots USB 2.0 ports Serial port DVD-ROM/CD-RW Remote Supervisor Adapter dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Seven PCIe (3 available) Two front, two rear D20281-18 Rev.11.0 10-5 IBM Netezza 1000-Series Site Preparation and Specifications Table 10-5: IBM x3850 X5 Host Specifications Feature Form factor Management Number 4U (7”) Description Rack-mountable IMM 10-6 D20281-18 Rev.11.0 C H A P T E R 11 1000-96 Specifications This chapter explains the following requirements for the 1000-96 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Space requirements The 1000-96 consists of a total of eight racks. The racks are bolted together into separate groups called pods. In this system there are a total of two pods of four racks. Rack Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The racks that are used for 1000-series systems are 1.5 in. (3.8 cm) wider than those used in previous Netezza systems. This means that each rack in the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Pods The 1000-96 consists of two separate pods. The space requirements for each pod are listed in Table 11-1. Table 11-1: 1000-96 Space Requirements Footprint Number of Racks Physical Pod 1 and Pod 2 4 102 in. by 43 in. (259.2 cm x 109.2 cm) Including Clearance 102 in. by 130 in. (259.2 cm x 330.2 cm) 11-1 IBM Netezza 1000-Series Site Preparation and Specifications Figure 11-1 shows the space requirements for each pod. 102 in (259.1 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 11-1: Space Requirements for each 4-Rack Pod When positioning the pods, they may be placed side-by-side, front-to-front, or rear-to-rear. Spacing between pods placed front-to-front or rear-to-rear must be as shown in Figure 11-2. 102 in (152 cm) Figure 11-2: Pod Positioning for Multiple Pods 11-2 D20281-18 Rev.11.0 Electrical Power Requirements Electrical Power Requirements Each 1000-96 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 11-2. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 11-2: 1000-96 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage 8 Pod 1 Pod 2 2 8 16 Total System 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 26,560 W 25,760 W 859 W/ft2 (9,242 W/m2) 52,320 W Circuit/Breaker Rating Connector Maximum Power Power/Area Environmental Requirements The 1000-96 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 11-3: 1000-96 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 178,523 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Humidity Cooling D20281-18 Rev.11.0 11-3 IBM Netezza 1000-Series Site Preparation and Specifications Floor Loading Requirements The floor that supports the 1000-96 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 11-4: 1000-96 Floor Loading Requirements Specification Maximum Weight Maximum Weight/Area Pod 1 8,000 lb (3628.8 kg) Pod 2 8,000 lb (3628.8 kg) 262.7 lb/ft2 (1,282.6 kg/m2) Host Server Specifications Table 11-5: IBM x3850 X5 Host Specifications Feature Processors Memory Power supplies Fans NIC NIC NIC Number four — two six two ports (two available) one quad port card (two available) three dual port card (internal use) one seven seven (three available) four one one 8X / 24X max Description Six-core Intel Xeon 2.0 GHz, 18MB L3 1066MHz 105w 128 GB, PC3-8500 (DDR3-1066) RDIMMs 1975W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Two Gigabit ethernet ports (embedded) One Quad Port 1 Gigabit Adapter Three Dual Port 10 Gigabit Adapter IMM port 300 GB SAS drives PCI slots USB 2.0 ports Serial port DVD-ROM/CD-RW Remote Supervisor Adapter dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Seven PCIe (3 available) Two front, two rear 11-4 D20281-18 Rev.11.0 Host Server Specifications Table 11-5: IBM x3850 X5 Host Specifications Feature Form factor Management Number 4U (7”) Description Rack-mountable IMM D20281-18 Rev.11.0 11-5 IBM Netezza 1000-Series Site Preparation and Specifications 11-6 D20281-18 Rev.11.0 C H A P T E R 12 1000-120 Specifications This chapter explains the following requirements for the 1000-120 system: Space requirements Electrical power requirements Environmental requirements Floor loading requirements Space requirements The 1000-120 consists of a total of ten racks. The racks are bolted together into separate groups called pods. In this system there are a total of three pods; two pods of four racks, and a single pod of two racks. Rack Each rack in the system has a footprint of 25.5 in. (64.8 cm) by 43 in. (109.2 cm). An additional 60 in. (152.4 cm) of clear space is required in front of each rack and 30 in. (76.2 cm) behind the rack. This is to allow unrestricted airflow and access to the system. Note: The racks that are used for 1000-series systems are 1.5 in. (3.8 cm) wider than those used in previous Netezza systems. This means that each rack in the 1000-series system is wider than a standard 24 in. (61 cm) data center floor tile. Plan accordingly. A full height system rack is 87.5 in. (222 cm) tall including its shipping pallet. Without the pallet, the rack stands 79.5 in. (202 cm) tall including casters. Allow for this when planning the movement of the system from the unloading point to its permanent location. Pods The 1000-120 consists of three separate pods. The space requirements for each pod are listed in Table 12-1. Table 12-1: 1000-120 Space Requirements Footprint Number of Racks Physical Pod 1 and Pod 2 4 102 in. by 43 in. (259.2 cm x 109.2 cm) Including Clearance 102 in. by 130 in. (259.2 cm x 330.2 cm) 12-1 IBM Netezza 1000-Series Site Preparation and Specifications Table 12-1: 1000-120 Space Requirements Footprint Number of Racks Physical Pod 3 2 51 in. by 43 in. (128.6 cm x 109.2 cm) Including Clearance 51 in. by 130 in. (128.6 cm x 330.2 cm) Figure 12-1 shows the space requirements for Pods 1 and 2. 102 in (259.1 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 12-1: Space Requirements for each 4-Rack Pod 12-2 D20281-18 Rev.11.0 Space requirements Figure 12-2 shows the space requirements for Pod 3. 51 in (129.6 cm) Rear 30 in (76 cm) 40 in (101.6 cm) Front 36 in (91.5 cm) Figure 12-2: Space Requirements for a 2-Rack Pod When positioning the pods, they may be placed side-by-side, front-to-front, or rear-to-rear. Spacing between pods placed front-to-front or rear-to-rear must be as shown in Figure 12-3. 102 in (152 cm) Figure 12-3: Pod Positioning for Multiple Pods D20281-18 Rev.11.0 12-3 IBM Netezza 1000-Series Site Preparation and Specifications Electrical Power Requirements Each 1000-120 system requires two separately protected power circuits. The power requirements for each circuit are listed in Table 12-2. Note: IBM Netezza recommends that the power supplied to the rack be uninterruptible. Table 12-2: 1000-120 Electrical Requirements Specification Circuits Total Plugs (Drops) Voltage 8 8 Pod 1 Pod 2 2 4 20 Pod 3 Total System 200-240/380-415 VAC, 50 Hz (EU models — 3-Phase Wye) 200-208 VAC, 60 Hz (NA models — 3-Phase Delta) 200-240 VAC, 50Hz/60 Hz (Single Phase) 30 Amps (EU models — 3-Phase Wye) 40 Amps (NA models — 3-Phase Delta) 60 Amps (Single Phase) IEC 309 32A 3P+N+G (EU models — 3-Phase Wye) IEC 309 60A 3P+G (NA models — 3-Phase Delta) IEC 309 60A 2P+G (Single Phase) 26,560 W 25,760 W 12,960 W 65,280 W Circuit/Breaker Rating Connector Maximum Power Power/Area 857 W/ft2 (9,225 W/m2) Environmental Requirements The 1000-120 system is designed to operate within the following temperature, humidity, and altitude ranges: Table 12-3: 1000-120 Operating Environment Operating Temperature Altitude 10°C to 35°C (50°F to 95°F) 0 to 3,048 m (0 to 10,000 ft) 20% to 80% non-condensing 222,745 BTU/hr Non-operating -15°C to 45°C (5°F to 113°F) 0 to 9,144 m (0 to 30,000 ft) 10% to 90% non-condensing — Humidity Cooling 12-4 D20281-18 Rev.11.0 Floor Loading Requirements Floor Loading Requirements The floor that supports the 1000-120 system must be capable of supporting a minimum of 263 lbs/ft2 (1,283 kg/m2). Table 12-4: 1000-120 Floor Loading Requirements Specification Maximum Weight Maximum Weight/Area Pod 1 8,000 lb (3628.8 kg) Pod 2 8,000 lb (3628.8 kg) 262.7 lb/ft2 (1,282.6 kg/m2) Pod 3 4,000 lb (1814.4 kg) Host Server Specifications Table 12-5: IBM x3850 X5 Host Specifications Feature Processors Memory Power supplies Fans NIC NIC NIC Number four — two six two ports (two available) one quad port card (two available) three dual port card (internal use) one seven seven (three available) four one one 4U (7”) 8X / 24X max Rack-mountable IMM Description Six-core Intel Xeon 2.0 GHz, 18MB L3 1066MHz 105w 128 GB, PC3-8500 (DDR3-1066) RDIMMs 1975W, Redundant, hot-pluggable N+1 Redundant, hot-pluggable Two Gigabit ethernet ports (embedded) One Quad Port 1 Gigabit Adapter Three Dual Port 10 Gigabit Adapter IMM port 300 GB SAS drives PCI slots USB 2.0 ports Serial port DVD-ROM/CD-RW Form factor Management Remote Supervisor Adapter dedicated NIC (10/100 Mb) Hot-swappable, in a RAID 10 configuration Seven PCIe (3 available) Two front, two rear D20281-18 Rev.11.0 12-5 IBM Netezza 1000-Series Site Preparation and Specifications 12-6 D20281-18 Rev.11.0 APPENDIX Model Comparison Table A-1: Model Comparison NPS System 1000-3 1000-6 1000-12 1000-18 1000-24 1000-36 1000-48 1000-72 1000-84 1000-96 1000-120 User Data 8 TB 16 TB 32 TB 48 TB 64 TB 96 TB 128 TB 192 TB 224 TB 256 TB 320 TB A Table A-1 provides a 1000-series model comparison. Host Processors 2 2 2 4 4 4 4 4 4 4 4 S-Blades 3 6 12 18 24 36 48 72 84 96 120 Racks 1 1 1 2 2 3 4 6 7 8 10 High Availability Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes A-1 IBM Netezza 1000-Series Site Preparation and Specifications A-2 D20281-18 Rev.11.0 APPENDIX Notices and Trademarks What’s in this appendix Notices Trademarks Open Source Notifications Regulatory and Compliance B This information was developed for products and services offered in the U.S.A. Notices IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not grant you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A. For license inquiries regarding double-byte character set (DBCS) information, contact the IBM Intellectual Property Department in your country or send inquiries, in writing, to: Intellectual Property Licensing Legal and Intellectual Property Law IBM Japan Ltd. 1623-14, Shimotsuruma, Yamato-shi Kanagawa 242-8502 Japan The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE B-1 IBM Netezza 1000-Series Site Preparation and Specifications IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Licensees of this program who wish to have information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which has been exchanged, should contact: IBM Corporation 26 Forest Street Marlborough, MA 01752 U.S.A. Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee. The licensed program described in this document and all licensed material available for it are provided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement or any equivalent agreement between us. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. All statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only. This information is for planning purposes only. The information herein is subject to change before the products described become available. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. B-2 D20281-18 Rev.11.0 Trademarks COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrate programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. The sample programs are provided "AS IS", without warranty of any kind. IBM shall not be liable for any damages arising out of your use of the sample programs. Each copy or any portion of these sample programs or any derivative work, must include a copyright notice as follows: © (your company name) (year). Portions of this code are derived from IBM Corp. Sample Programs. © Copyright IBM Corp. _enter the year or years_. All rights reserved. If you are viewing this information softcopy, the photographs and color illustrations may not appear. Trademarks IBM, the IBM logo, and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at www.ibm.com/legal/copytrade.shtml. Netezza, the Netezza logo, the circle-N logo, TwinFin, Skimmer, Snippet Blades, S-Blades, NPS, Snippet, Snippet Processing Unit, SPU, Snippet Processing Array, SPA, Performance Server, Netezza Performance Server, Asymmetric Massively Parallel Processing, AMPP, Intelligent Query Streaming and other marks are trademarks or registered trademarks of Netezza Corporation, an IBM Company, in the United States and/or other countries. All rights reserved. The following terms are trademarks or registered trademarks of other companies: Adobe is a registered trademark of Adobe Systems Incorporated in the United States, and/ or other countries. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corppration in the United States, other countries, or both. NEC is a registered trademark of NEC Corporation. UNIX is a registered trademark of The Open Group in the United States and other countries. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Red Hat is a trademark or registered trademark of Red Hat, Inc. in the United States and/or other countries. D-CC, D-C++, Diab+, FastJ, pSOS+, SingleStep, Tornado, VxWorks, Wind River, and the Wind River logo are trademarks, registered trademarks, or service marks of Wind River Systems, Inc. Tornado patent pending. D20281-18 Rev.11.0 B-3 IBM Netezza 1000-Series Site Preparation and Specifications APC and the APC logo are trademarks or registered trademarks of American Power Conversion Corporation. All document files and software of the above named third-party suppliers are provided "as is" and may contain deficiencies. Netezza and its suppliers disclaim all warranties of any kind, express or implied, including, without limitation, those of merchantability, fitness for a particular purpose, and non infringement. In no event will Netezza or its suppliers be liable for indirect, incidental, consequential, special, or economic damages (including lost business profits, business interruption, loss or damage of data, and the like), or the use or inability to use the above-named third-party products, even if Netezza or its suppliers have been advised of the possibility of such damages. Other company, product or service names may be trademarks or service marks of others. Open Source Notifications PostgreSQL Portions of this publication were derived from PostgreSQL documentation. For those portions of the documentation that were derived originally from PostgreSQL documentation, and only for those portions, the following applies: PostgreSQL is copyright © 1996-2001 by the PostgreSQL global development group and is distributed under the terms of the license of the University of California below. Postgres95 is copyright © 1994-5 by the Regents of the University of California. Permission to use, copy, modify, and distribute this documentation for any purpose, without fee, and without a written agreement is hereby granted, provided that the above copyright notice and this paragraph and the following two paragraphs appear in all copies. In no event shall the University of California be liable to any party for direct, indirect, special, incidental, or consequential damages, including lost profits, arising out of the use of this documentation, even if the University of California has been advised of the possibility of such damage. The University of California specifically disclaims any warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The documentation provided hereunder is on an "as-is" basis, and the University of California has no obligations to provide maintenance, support, updates, enhancements, or modifications. ICU Library The Netezza implementation of the ICU library is an adaptation of an open source library Copyright (c) 1995-2003 International Business Machines Corporation and others. ICU License - ICU 1.8.1 and later COPYRIGHT AND PERMISSION NOTICE Copyright (c) 1995-2003 International Business Machines Corporation and others All rights reserved. Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, and/or sell copies of the Software, and to permit persons to whom the Software B-4 D20281-18 Rev.11.0 Open Source Notifications is furnished to do so, provided that the above copyright notice(s) and this permission notice appear in all copies of the Software and that both the above copyright notice(s) and this permission notice appear in supporting documentation. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR HOLDERS INCLUDED IN THIS NOTICE BE LIABLE FOR ANY CLAIM, OR ANY SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES, OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE. Except as contained in this notice, the name of a copyright holder shall not be used in advertising or otherwise to promote the sale, use or other dealings in this Software without prior written authorization of the copyright holder. ODBC Driver The Netezza implementation of the ODBC driver is an adaptation of an open source driver, Copyright © 2000, 2001, Great Bridge LLC. The source code for this driver and the object code of any Netezza software that links with it are available upon request to sourcerequest@netezza.com Botan License Copyright (C) 1999-2008 Jack Lloyd 2001 Peter J Jones 2004-2007 Justin Karneges 2005 Matthew Gregan 2005-2006 Matt Johnston 2006 Luca Piccarreta 2007 Yves Jerschow 2007-2008 FlexSecure GmbH 2007-2008 Technische Universitat Darmstadt 2007-2008 Falko Strenzke 2007-2008 Martin Doering 2007 Manuel Hartl 2007 Christoph Ludwig 2007 Patrick Sona All rights reserved. Redistribution and use in source and binary forms, for any use, with or without modification, of Botan (http://botan.randombit.net/license.html) is permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions, and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions, and the following disclaimer in the documentation and/or other materials provided with the distribution. THIS SOFTWARE IS PROVIDED BY THE AUTHOR(S) "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED. D20281-18 Rev.11.0 B-5 IBM Netezza 1000-Series Site Preparation and Specifications IN NO EVENT SHALL THE AUTHOR(S) OR CONTRIBUTOR(S) BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITYOF SUCH DAMAGE. Regulatory and Compliance Regulatory Notices Install the NPS system in a restricted-access location. Ensure that only those trained to operate or service the equipment have physical access to it. Install each AC power outlet near the NPS rack that plugs into it, and keep it freely accessible. Provide approved 30A circuit breakers on all power sources. Product may be powered by redundant power sources. Disconnect ALL power sources before servicing. High leakage current. Earth connection essential before connecting supply. Courant de fuite élevé. Raccordement à la terre indispensable avant le raccordement au réseau. Homologation Statement Attention: This product is not intended to be connected directly or indirectly by any means whatsoever to interfaces of public telecommunications networks, neither to be used in a Public Services Network. FCC - Industry Canada Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense. This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. WEEE Netezza Corporation is committed to meeting the requirements of the European Union (EU) Waste Electrical and Electronic Equipment (WEEE) Directive. This Directive requires producers of electrical and electronic equipment to finance the takeback, for reuse or recycling, of their products placed on the EU market after August 13, 2005. CE Statement (Europe) This product complies with the European Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC as amended by European Directive 93/68/EEC. B-6 D20281-18 Rev.11.0 Regulatory and Compliance Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. VCCI Statement こ の装置は、 情報処埋装置等電波障害自主規制協議会   (VCCI) の基準 に基づ く ク ラ ス A 情報技術装置です。 こ の装置を家庭環境で使用す る と 電波 妨害 を 引 き 起越す こ と が あ り ま す。 こ の場合には使用者が適切な対策 を 講ず る う 要求 さ れ る こ と があ り ます。 D20281-18 Rev.11.0 B-7 IBM Netezza 1000-Series Site Preparation and Specifications B-8 D20281-18 Rev.11.0
Fly UP